Technical Product Specification
Firmware Functional Specification Intel® Local Control Panel for EPSD Platforms TPS
Intel order number G83726-001 Revision 1.0
10
3.5.2 System Information (SI)
Selecting SI item in the View menu displays the following screen.
Figure 14: System Information menu
The menu items for the above screen are described below:
SN (System Name): Value specified in the product name in the product FRU information
in the main board BMC FRU.
SM (Server Model): Value specified in the product part number in the product FRU
information in the main board BMC FRU.
AT (Asset Tag): Value specified in the product asset tag in the product FRU information
in the main board BMC FRU.
SGUID (System GUID): System UUID stored by BIOS.
CSTR (Customizable String): Custom string placed by the OEM\end user.
Selecting any item in the above screen displays its value.
3.5.3 BMC LAN (BL) Configuration
Selecting BL item in the View menu displays the following screen.
Figure 15: BMC LAN Configuration
The items displayed on selection of the above menu options are as follows:
IPSource: Source of the BMC IP address will be displayed. Either Static or DHCP will
be displayed on selecting this item.
IPAddr: Displays the BMC IP address.
SMask: Displays the subnet mask of the BMC.
GWay: Displays default Gateway of the BMC.
3.5.4 RMM LAN (RL) Configuration
Selecting RL item in the View menu displays the same screen as above, but selection of
individual items displays the values of RMM (Remote Management Module) rather than that of
BMC.
|SN|SM|AT|SGUID|CSTR
|IPSource|IPAddr|SMask|GWay