Technical Product Specification

Installing and Removing the Intel® Local Control Panel Intel® Local Control Panel for EPSD Platforms TPS
Intel order number G83726-001 Revision 1.0
20
Figure 32: Installing the cage in a 2U server system
15. For 2U system with 2.5” hard drive configuration, install the stiffener. Please refer to the
Intel
®
Server System Service Guide for detailed instructions.
4.4 Removing the Intel
®
A1U2ULCP Local Control Panel in a 2U server
system
1. Remove the system top cover.
2. For 2U system with 2.5” hard drive configuration, remove the stiffener first. Please refer
to the Intel
®
Server System Service Guide for detailed instructions.
3. Disconnect the Intel
®
Local Control Panel cable, the front USB cable and the front panel
cable from the server board (see letter A).
4. For 2U system with 2.5” hard drive configuration, remove the three screws to release the
hard drive cage (see letter B). For 2U system with 3.5” hard drive configuration, remove
the six screws to release the hard drive cage. Please refer to the Intel
®
Server System
Service Guide for detailed instructions.
5. Slide out the cage from server chassis together with cables (see letter C).