User Guide
Intel® BMC And RMM4 User Guide Intel® Integrated BMC Web Console Options
Revision 2.8 Intel order number H54847-001 121
On Intel
®
Server Boards and Systems Based on Intel
®
Xeon
®
Processor
E5-4600/2600/2400/1600/1400 (v1&v2) Product Families you have an additional option
Force-enter BIOS Setup on a reset. See Figure 105 and Table 27 for details.
For the Graceful OS Shutdown to function properly the OS must be ACPI aware and be
configured to do the shutdown without operator intervention. After a Graceful Shutdown has
been requested, if the system does not shut down as requested, the command cannot be
executed again for five minutes.
Figure 105: Remote Control Server Power Control Page on Intel
®
Server Boards and Systems Based
on Intel
®
Xeon
®
Processor E5-4600/2600/2400/1600/1400 (v1&v2) Product Families
Table 27: Remote Control Power Control Options on Intel
®
Server Boards and Systems Based on
Intel
®
Xeon
®
Processor E5-4600/2600/2400/1600/1400 (v1&v2) Product Families
Option Task
Reset Server
Select option to hard reset the host without powering off.
Force-Enter BIOS Setup
Check this option to enter into the BIOS setup after resetting the server.
Power OFF Server
Select option to immediately power off the host.
Graceful Shutdown
Select option to soft power off the host.
Power ON Server
Select option to power on the host.
Power Cycle Server
Select option to immediately power off the host, and then power it back on after one second.
Perform Action button Click to execute the selected remote power command.