User Guide
Intel® Integrated BMC Web Console Options Intel® BMC And RMM4 User Guide
122 Intel order number H54847-001 Revision 2.8
Option Task
Note: All power control actions are done through the BMC and are immediate actions.
On an S1200V3RP and Intel® Server Boards and Systems Based on Intel® Xeon® Processor E5-
2600 V3 --- S2600WT, S2600KP, S2600TP and S2600CW ’ system you have an additional
option Force-enter BIOS Setup on a Power On. See Figure 106 and Table 28 for details.
For the Graceful OS Shutdown to function properly the OS must be ACPI aware and be
configured to do the shutdown without operator intervention. After a Graceful Shutdown has
been requested, if the system does not shut down as requested, the command cannot be
executed again for five minutes.
Figure 106: Remote Control Server Power Control Page on S1200V3RP and Intel
®
Server Boards and
Systems Based on Intel
®
Xeon
®
Processor E5-2600 V3 --- S2600WT, S2600KP, S2600TP and
S2600CW
Table 28: Remote Control Power Control Options on S1200V3RP Product Family
Option Task
Reset Server
Select option to hard reset the host without powering off.
Force-Enter BIOS Setup
Check this option to enter into the BIOS setup after resetting the server.
Power OFF Server
Select option to immediately power off the host.
Graceful Shutdown
Select option to soft power off the host.