User Guide

Hardware Installations and Initial Configuration Intel® BMC And RMM4 User Guide
20 Intel order number H54847-001 Revision 2.8
3.3.2.1.4 Installing the Dedicated NIC on Intel
®
Server System R2000FP Family or
R2000SC Family
1. Ensure that AC power has been removed from the system and that you have waited at
least 30 seconds after removing power.
2. Attach the metal fastening bracket to the Intel
®
Dedicated Server Management NIC module.
Figure 11: Attaching the Bracket to the Intel
®
Dedicated Server Management NIC Module
3. Remove the Filler Panel and Retention Device. See A in Figure 12.
4. Secure the metal fastening bracket with the NIC module to the PCI slot bracket with two
screws as shown in B of Figure 12. This will align the RJ-45 with the opening in the PCI slot
bracket.
5. Fasten the bracket with one screw as shown in C of Figure 12.