User Guide
Hardware Installations and Initial Configuration Intel® BMC And RMM4 User Guide
22 Intel order number H54847-001 Revision 2.8
Table 5: Intel
®
Rack Optimized Server Systems
Intel
®
Server System
R1000JP
3.3.2.4 Installation of the Intel
®
Dedicated Server Management NIC on an Intel
®
Pedestal Server System
Most Intel
®
Pedestal Server Systems allow the Intel
®
Dedicated Server Management NIC
module to be mounted to the chassis. Table 6 lists all Intel
®
Pedestal Server Systems that
support a chassis mounted Intel
®
Dedicated Server Management NIC module. Use the
following steps when installing the Intel
®
Dedicated Server Management NIC module on those
server systems:
1. Ensure that AC power has been removed from the system and that you have waited at
least 10 seconds after removing power.
2. Attach the metal fastening bracket to the Intel
®
Dedicated Server Management NIC module.
Figure 13: Attaching the Bracket to the Intel
®
Dedicated Server Management NIC Module
Note: For the next two steps see your specific Intel
®
Server Systems Technical Product
Specification and Intel
®
Server Systems Service Guide for more details. Table 6 lists the figure
showing the installation for that specific system.
3. Push out and remove the metal cover on the chassis where the NIC RJ-45 receptacle will
align.
Caution: Carefully remove the metal cover with pliers; directly removing it with fingers has
a potential risk.