Enclosure Management Cabling for Intel C200 Series Chipset and Intel C600 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures

Enclosure Management Cabling Guide for Inte C200 and C600 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures
8
Step 2: Choose a proper drive fault LED management cable between RAID controller and backplane.
Item
SAS/SATA port type
on RAID controller
SAS/SATA port
type on backplane
SGPIO Cables selected
Cable shape
5
SATA
SATA
SGPIO Y cable (G10943-
xxx: 5-pin header on one
end. 5-pin and 4-pin
headers on the other end.
For use with
RMS2AF0x0,RMS2LL0x0,
or onboard RAID.)
SGPIO cable (G22461-xxx:
5-pin headers on both ends.
For use with onboard
RAID.)
6
Mini-SAS
SATA
Mini-SAS to SATA cable
(G17758-xxx: with 5-pin
SGPIO)
7
SATA
Mini-SAS
SATA to mini-SAS cable
(G14989-xxx, with 5-pin
SGPIO)
8
Mini-SAS
Mini-SAS
Mini-SAS to mini-SAS cable