Enclosure Management Cabling for Intel C200 Series Chipset and Intel C600 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures

Enclosure Management Cabling Guide for Intel® C200 and C600 Series Chipset Based Server Systems with Hot -Swap Drive Enclosures
10
Step 2: Choose a proper SAS/SATA cable between expander and backplane.
Item
SAS/SATA port
type on backplane
SAS/SATA cables type
SAS/SATA cable shape
11
SATA*
Mini-SAS to SATA cable
(G17758-xxx: with 5-pin
SGPIO)
12
Mini-SAS
Mini-SAS to mini-SAS cable
Note *: Only 1U rack 4 x 3.5 backplane and Pedestal 4 x 3.5 backplane have SATA ports. Its not recommended to use expander between
RAID controller and either backplane.
Step 3: Choose a proper drive fault LED management cable between expander and backplane.
Item
SAS/SATA port
type on backplane
SGPIO Cables selected
Cable shape
13
SATA*
Mini-SAS to SATA cable
(G17758-xxx: with 5-pin
SGPIO)
SGPIO Y cable (G10943-
xxx: 5-pin header on one
end. 5-pin and 4-pin
headers on the other end.
For use with
RMS2AF0x0,RMS2LL0x0,
or onboard RAID.)
14
Mini-SAS
Use SGPIO pins inside the
Mini-SAS to mini-SAS cable