Enclosure Management Cabling for Intel C200 Series Chipset and Intel C600 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures
October, 2012
19
4. Connector Pinout Definition
SATA Connector Shape
SATA connector can support both SAS and SATA devices through backplanes. Below signal names are with respect to the host; the
device connected to the host reverses the signal names. Transmit pins connect to receive pins on the other device. The SAS/SATA
connector is keyed at pin 1.
SATA Connector Pin-out
Pin #
Signal
Description
1
GND
Ground
2
TX0+
Transmitter differential pair
3
TX0-
Transmitter differential pair
4
GND
Ground
5
RXD-
Receiver differential pair
6
RXD+
Receiver differential pair
7
GND
Ground
On Intel
®
C200 or C600 Series Chipset based Server Boards and Systems, all MiniSAS (SFF8087) internal connectors are 36pin which
includes 8pin SGPIO signals. The miniSAS-to-miniSAS and miniSAS-to-SATA cables must include the 8pin SGPIO signals, otherwise
cannot support RAID enclosure management function.