Enclosure Management Cabling for Intel C200 Series Chipset and Intel C600 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures
Enclosure Management Cabling Guide for Intel® C200 and C600 Series Chipset Based Server S ystems with Hot-Swap Drive Enclosures
20
36pin MiniSAS (SFF8087) Internal Connector with one SGPIO Connector Pin-out
Controller Connector Pin-out
Backplane Connector Pin-out
Port
SFF-8087 Pin #
Pin Definition
Pin #
Pin Definition
A1
GND
7
GND
Port 0
A2
RX0+
6
TX+
A3
RX0-
5
TX-
B1
GND
4
GND
B2
TX0+
2
RX-
B3
TX0-
3
RX+
B4
GND
1
GND
A4
GND
7
GND
Port 1
A5
RX1+
6
TX+
A6
RX1-
5
TX-
A7
GND
4
GND
B5
TX1+
2
RX-
B6
TX1-
3
RX+
B7
GND
1
GND
B8
SB0/SCLK/SCL
1
SCLK
SGPIO
B9
SB1/SLOAD/SDA
2
SLOAD
B10
SB2/GND
4
GND
A9
SB3/GND
A10
SB4/SDATA_OUT/RST
3
SDATAOUT0
A11
SB5/SDATA_IN/ADDR
A8
SB7/BP_TYPE
B11
SB6/CTLR_TYPE
A12
GND
7
GND
Port 2
A13
RX2+
6
TX+
A14
RX2-
5
TX-
B12
GND
4
GND
B13
TX2+
2
RX-
B14
TX2-
3
RX+
B15
GND
1
GND
A15
GND
7
GND
Port 3
A16
RX3+
6
TX+
A17
RX3-
5
TX-