Server Management Guide
Baseboard Management Controller
16 Intel
®
Server Boards and Server Platforms Server Management Guide
Figure 4. Restart RMM2
6. Check/confirm RMM2’s IP address by psetup or kiratool (DHCP IP address could be changed after
RMM2 reset)
7. Restart BMC by doing:
> syscfg /rbmc
8. User IPMITOOL to access BMC through Intel
®
RMM2’s dedicate NIC:
> ipmitool -I lan -H 10.239.56.103 -U "admin" -P "password" fru
NOTE
Here “10.239.56.103” is an example of Intel
®
RMM2’s IP address. Your BMC’s configuration about user
name and IP address may be varied.
2.3 BMC in Intel
®
S3200/X38ML server boards
2.3.1 LAN interface
Intel
®
S3200/X38ML server boards are embedded with Integrated BMC. The BMC implements both
the IPMI 1.5 and IPMI 2.0 messaging models. These provide out-of-band local area network (LAN)
communication between the BMC and the external world.
The BMC supports a maximum of one LAN interface:
Intel
®
S3200SH and Intel
®
X38ML server boards support two LAN interfaces for operating
system use but only NIC1 is able to handle BMC server management traffic.