Specification update

Monthly Specification Update Intel® Server Boards & Systems
8
Implication The SEL log may indicate that system has an occasional reset in a normal
POST during DC cycle test (global reset).
Status This issue was fixed in BMC 1.04.
Workaround None.
11. System may continuously report a faulty or assert/deassert log when
having blank HDD carriers or un-configured HDDs
Problem With ESRT2 SATA RAID 5 config with 3 HDDs, put the 4th HDD in drive carrier
and set it to either unconfigured or global hot spare. System event log may be
flooded with HDD faulty entries.
With ESRT2 SAS RAID 1 with 2 HDDs, put 3rd HDD and set to unconfigured or
global hot spare. System event log may be flooded flood with HDD faulty
entries.
Implication User may see the SEL flooded with HDD faulty entries when either of the two
scenarios above are used.
Status This issue was fixed in BMC 1.04 and later version.
Workaround None.
12. Integrated BMC Web Console Power Statistics page Minimum
wattage reads as zero.
Problem On some systems the Integrated BMC Web Console Power Statistic page may
display the Minimun wattage as zero (0W) after the system has been powered.
This reading will stay at zero until the next power cycle of the system.
Implication This is an incorrect reading only and does not affect operation.
Status This issue is fixed in BMC release 1.10 and later version
Workaround None.
13. Integrated BMC Web Console Power Control page Perform Action
button not functional.
Problem After performing a Graceful shutdown from the Integrated BMC Web Console
Power Control page the Perform Action button gets grayed out and cannot be
pressed to request another action.
Implication You cannot perform a power on of the system.
Status This issue is fixed in BMC release 1.10 and later version