Specification update

Intel® Server Boards & Systems Monthly Specification Update
9
Workaround Select another page in the Integrated BMC Web Console and then return to the
Power Control Page. The Perform Action button will then be available.
14. IPMI Get Chassis Status command returns incorrect Chassis Identify
State.
Problem When a Get Chassis Status command is issued, after the Chassis Identify LED
has been forced on, the status of off (00b) is returned for Chassis Identify State
(response data byte 4 bits [5:4]).
Implication Unable to correctly read when the Chassis Identify LED is on.
Status This issue is fixed in BMC release 1.10 and later version
Workaround None.
15. The BIOS and ME Firmware can't be updated successfully via Intel® One
Boot Flash Update Utility(OFU) under SuSE Linux Enterprise Server 11*
(64-bit) with SP2
Problem OFU will fail to update BIOS & ME under SuSE Linux Enterprise Server 11*
(64-bit) with SP2 Operating System.
Implication If the system is running SuSE Linux Enterprise Server 11* (64-bit) with SP2
Operating System, using OFU to update System Firmware Update
Package(SFUP) will fail.
Status This issue is fixed in OFU Version 11.0 Build 8.
Workaround Update System Firmware Update Package(SFUP) from EFI environment using
iFlash32, FWPIAUpdate and FRUSDR Utility
16. BMC continuously sends HDD assert/de-assert event during HDD RAID
rebuild under ESRT2 mode of the SCU controller
Problem HDD fault will keep asserting and de-asserting frequent during RAID rebuild
under ESRT2
Implication During HDD ESRT2 RAID rebuild, there's flood HDD fault assert/deassert(SAS
RAID) or Rebuild/remap (SATA RAID) logs into SEL.
Status This issue is fixed in ESRT2 driver release 15.00.0528.2012 and later version
Workaround None.