Technical product specification
Intel
®
Server Board S2600CP and Server System P4000CP TPS
Intel® Server Board S2600CP Connector/Header Locations and Pin-outs
Revision 1.8
Intel order number G26942-005
93
Table 34. SATA SGPIO Connector Pin-out
Pin
Signal Name
1
SCLK
2
SLOAD
3
GND
4
SDATAOUT0
5
SDATAOUT1
7.3.4 SAS Connectors
The server board includes eight SAS/SATA connectors. By default, only the connectors labeled
from “SAS_0” to “SAS_3” are enabled and support transfer rates of up to 3Gb/s. The connectors
labeled from “SAS_4” to “SAS_7” are only enabled when an optional Intel
®
RAID C600 Upgrade
Key is installed. The following tables provide the pin-out for each connector.
Table 35. SAS/SATA Connector Pin-out
Pin
Signal Name
1
GND
2
SATA_TX_P
3
SATA_TX_N
4
GND
5
SATA_RX_N
6
SATA_RX_P
7
GND
7.3.5 SAS SGPIO Connectors
Table 36. SAS SGPIO Connector Pin-out
Pin
Signal Name
Pin
Signal Name
1
CLOCK
2
LOAD
3
GND
4
DATAOUT
5
DATAIN
7.3.6 Intel
®
RAID C600 Upgrade Key Connector
The server board provides one connector to support Intel
®
RAID C600 Upgrade Key. The Intel
®
RAID C600 Upgrade Key is a small PCB board that enables different versions of RAID 5
software stack and/or upgrade from SATA to SAS storage functionality. The pin configuration of
connector is identical and defined in the following table.
Table 37. Intel
®
RAID C600 Upgrade Key Connector Pin-out
Pin
Signal Name
1
GND
2
FM_PBG_DYN_SKU_KEY
3
GND
4
FM_SSB_SAS_SATA_RAID_KEY