Note: Current SCU controller design limitations prevent any hard drive attached to a SAS
expander card from being a boot device when all SCU connectors are attached to the SAS
expander card.
For storage configurations that require utilizing a hard disk drive as the boot device, the system
must be cabled as follows to ensure a boot device is found and for contiguous drive mapping (0-
16).
The SCU port 0-3 (labeled as “SAS 0” through “SAS 3”) connector on the server board is
cabled to the first mini-SAS connector on the hot swap backplane.
The SCU port 4-7 (labeled as “SAS 4” through “SAS 7”) connector on the server board is
cabled to Connector A on the SAS expander card.
Cables from the SAS Expander to the hot swap backplane must be connected in order
from connector B to connector F.