Technical product specification
Intel
®
Server Board S2600CP and Server System P4000CP TPS Intel
®
Server System P4000CP Thermal Management
Revision 1.8
Intel order number G26942-005
125
Figure 49. Fixed Fans in Intel
®
Server Chassis
Note: If Quiet Fan Idle Mode is enabled, with combination of Altitude set to [300m or less] or
[301m-900m] and Fan Profile set to [Acoustic] mode, the core fan will stop running when the
aggregate sensor temperatures are satisfied indicating the system is at good thermal/light
loading conditions. For other scenarios, the core fan will maintain a minimum RPM.
12.3.2 Acoustic
The Intel
®
Server System P4308CP4MHEN acoustic is measured with typical configuration and
typical operating working conditions.
Table 63. Acoustic level for Intel
®
Server System P4308CP4MHEN
System Configuration
P4308CP4MHEN
1,2
CPU
2x 130-W
Memory
16x DR*8
HDD
4x3.5 Hotswap
Add-in card
3x PCI
Fans
2x Non redundant
PSU
550W
Declared Acoustic
OS idle: 4.89
TO1: 5.08
3
TO2: 5.07
4
Notes:
1. System is at or below 900m altitude and set to acoustic mode.
2. Quiet Fan Idle Mode is enabled.
3. TO1 - Typical operating mode 1: processor and HDD stressed.
4. TO2 – Typical operating mode 2: processor, memory, HDD stressed.
12.4 Intel
®
Server System P4308CP4MHGC and P4208CP4MHGC
The Intel
®
Server System P4308CP4MHGC and P4208CP4MHGC consist of five 80x38mm
replaceable hot-swap fans providing redundant cooling for all ingredients inside the enclosure.
When a single fan failed, the remaining of the four fans will adjust the fan speed to maintain
sufficient system cooling. The five 80x38mm fans deliver same cooling capability and are
interchangeable.