13.2.2 Temperature Requirements
The power supply shall operate within all specified limits over the T
op
temperature range.
Table 71. Thermal Requirements
Item
Description
Min
Max
Units
T
op
Operating temperature range.
0
50
ºC
T
non-op
Non-operating temperature range.
-40
70
ºC
Altitude
Maximum operating altitude.
3000
meters
13.2.3 AC Input Requirements
13.2.3.1 Power Factor
The power supply meets the power factor requirements stated in the Energy Star
®
Program
Requirements for Computer Servers. These requirements are stated below.
Table 72. Power Factor Requirements for Computer Servers
Output power
20% load
50% load
100% load
Power factor
0.8
0.9
0.95
Tested at 230Vac, 50Hz and 60Hz and 115VAC, 60Hz.
Tested according to Generalized Internal Power Supply Efficiency Testing Protocol Rev 6.4.3.
This is posted at
http://efficientpowersupplies.epri.com/methods.asp.
13.2.3.2 AC Inlet Connector
The AC input connector is an IEC 320 C-14 power inlet.
This inlet is rated for 10A/250VAC.
13.2.3.3 AC Input Voltage Specification
The power supply operates within all specified limits over the following input voltage range.
Harmonic distortion of up to 10% of the rated line voltage does not cause the power supply to
go out of specified limits. Application of an input voltage below 85VAC does not cause damage
to the power supply, including a blown fuse.
Table 73. AC Input Voltage Range
Parameter
Min
Rated
Vmax
Start up vac
Power off
vac
Voltage (110)
90 V
rms
100-127 V
rms
140 V
rms
85VAC +/-
4VAC
70VAC +/-
5VAC
Voltage (220)
180 V
rms
200-240 V
rms
264 V
rms
Frequency
47 Hz
50/60
63 Hz
Notes:
1. Maximum input current at low input voltage range shall be measured at 90VAC, at maximum load.
2. Maximum input current at high input voltage range shall be measured at 180VAC, at maximum load.
3. This requirement is not to be used for determining agency input current markings.