Technical product specification
Intel
®
Server System P4000CP Power System Options Intel
®
Server Board S2600CP and Server System P4000CP TPS
Revision 1.8
Intel order number G26942-005
144
Power Supply Condition
LED State
Power supply FW updating.
2Hz Blink GREEN
13.3.1.4 Temperature Requirements
The power supply operates within all specified limits over the T
op
temperature range. All airflow
passes through the power supply and not over the exterior surfaces of the power supply.
Table 93. Environmental Requirements
Item
Description
Min
Max
Units
T
op_sc_red
Operating temperature range; spreadcore redundant
(60% load, 3000m, spreadcore system flow impedance
1
)
0
60
C
T
op_sc_nr
Operating temperature range; spreadcore non-redundant
(100% load, 3000m, spreadcore system flow impedance
1
)
0
50
C
T
op_rackped_
900
Operating temperature range; rack/pedestal 900m
(100% load, 900m, rack/pedestal system flow impedance
1
)
0
45
C
T
op_rackped_
3000
Operating temperature range; rack/pedestal 3000m
(100% load, 3000m, rack/pedestal system flow impedance
1
)
0
40
C
Texit
Maximum exit air temperature
68
C
T
non-op
Non-operating temperature range
-40
70
C
Altitude
Maximum operating altitude
2
3050
m
Notes:
1. Under normal conditions, the exit air temperature shall be less than 65C. 68C is provided for absolute
worst case conditions and is expected only to exist when the inlet ambient reaches 60C.
2. T
op_rackped_900
condition only requires maximum altitude of 900m.
The power supply meets UL enclosure requirements for temperature rise limits. All sides of the
power supply, with exception to the air exhaust side, are classified as “Handle, knobs, grips, and
so on”, and held for short periods of time only.
13.3.2 AC Input Requirements
13.3.2.1 Power Factor
The power supply meets the power factor requirements stated in the Energy Star
®
Program
Requirements for Computer Servers. These requirements are stated below.
Table 94. Power Factor Requirements for Computer Servers
Output power
10% load
20% load
50% load
100% load
Power factor
> 0.65
> 0.80
> 0.90
> 0.95
Tested at 230Vac, 50Hz and 60Hz and 115VAC, 60Hz
Tested according to Generalized Internal Power Supply Efficiency Testing Protocol Rev 6.4.3.
This is posted at http://efficientpowersupplies.epri.com/methods.asp.
13.3.2.2 AC Inlet Connector
The AC input connector is an IEC 320 C-14 power inlet. This inlet is rated for 10A/250VAC.