Technical product specification

Appendix C: BMC Sensor Tables Intel
®
Server Board S2600CP and Server System P4000CP TPS
Revision 1.8
Intel order number G26942-005
180
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset
Triggers
Contrib. To
System Status
Assert/
De-
assert
Readable
Value/Off
sets
Event
Data
Rearm
Stand-
by
(Physical Scrty)
chassis-
specific
05h
6Fh
04 - LAN leash
lost
OK
FP Interrupt
(FP NMI Diag Int)
05h
Chassis -
specific
Critical
Interrupt
13h
Sensor
Specific
6Fh
00 - Front
panel
NMI/diagnostic
interrupt
OK
As
Trig
Offset
A
SMI Timeout
(SMI Timeout)
06h
All
SMI
Timeout
F3h
Digital
Discrete
03h
01 State
asserted
Fatal
As and
De
Trig
Offset
A
System Event Log
(System Event Log)
07h
All
Event
Logging
Disabled
10h
Sensor
Specific
6Fh
02 - Log area
reset/cleared
OK
As
Trig
Offset
A
X
System Event
(System Event)
08h
All
System
Event
12h
Sensor
Specific
6Fh
02 -
Undetermined
system H/W
failure
04 PEF
action
Fatal
OK
As and
De
As
-
Trig
Offset
A
X
Button Sensor
(Button)
09h
All
Button/Swi
tch
14h
Sensor
Specific
6Fh
00 Power
Button
02 Reset
Button
OK
AS
_
Trig
Offset
A
X
BMC Watchdog
0Ah
All
Mgmt
System
Health
28h
Digital
Discrete
03h
01 State
Asserted
Degraded
As
Trig
Offset
A
-
Voltage Regulator
Watchdog
(VR Watchdog)
0Bh
All
Voltage
02h
Digital
Discrete
03h
01 State
Asserted
Fatal
As and
De
Trig
Offset
M
X
Fan Redundancy
1
0Ch
Chassis-
specific
Fan
Generic
00 - Fully
redundant
OK
As and
De
Trig
Offset
A