Technical product specification

Intel
®
Server Board S2600CP and Server System P4000CP TPS Appendix C: BMC Sensor Tables
Revision 1.8
Intel order number G26942-005
185
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset
Triggers
Contrib. To
System Status
Assert/
De-
assert
Readable
Value/Off
sets
Event
Data
Rearm
Stand-
by
Network Interface
Controller Temperature
(LAN NIC Temp)
2Fh
All
Temperatu
re
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
R, T
A
X
Fan Tachometer Sensors
(Chassis specific
sensor names)
30h
3Fh
Chassis
and
Platform
Specific
Fan
04h
Threshold
01h
[l] [c,nc]
nc =
Degraded
c = Non-
fatal
2
As and
De
Analog
R, T
M
-
Fan Present Sensors
(Fan x Present)
40h
4Fh
Chassis
and
Platform
Specific
Fan
04h
Generic
08h
01 - Device
inserted
OK
As and
De
-
Trigger
ed
Offset
Auto
-
Power Supply 1 Status
(PS1 Status)
50h
Chassis-
specific
Power
Supply
08h
Sensor
Specific
6Fh
00 - Presence
OK
As and
De
Trig
Offset
A
X
01 - Failure
Degraded
02 Predictive
Failure
Degraded
03 - A/C lost
Degraded
06
Configuration
error
OK
Power Supply 2 Status
(PS2 Status)
51h
Chassis-
specific
Power
Supply
08h
Sensor
Specific
6Fh
00 - Presence
OK
As and
De
Trig
Offset
A
X
01 - Failure
Degraded
02 Predictive
Failure
Degraded
03 - A/C lost
Degraded
06
Configuration
error
OK
Power Supply 1
AC Power Input
(PS1 Power In)
54h
Chassis-
specific
Other
Units
0Bh
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
R, T
A
X