Technical product specification
Intel
®
Server Board S2600CP and Server System P4000CP TPS Appendix C: BMC Sensor Tables
Revision 1.8
Intel order number G26942-005
189
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset
Triggers
Contrib. To
System Status
Assert/
De-
assert
Readable
Value/Off
sets
Event
Data
Rearm
Stand-
by
Processor 4 DTS Thermal
Margin
(P4 DTS Therm Mgn)
86h
All
Temperatu
re
01h
Threshold
01h
-
-
-
Analog
R, T
A
–
Processor2 MSID
Mismatch
(P2 MSID Mismatch)
87h
All
Processor
07h
Digital
Discrete
03h
01 – State
Asserted
fatal
As and
De
–
Trig
Offset
M
–
Processor 1 VRD
Temperature
(P1 VRD Hot)
90h
All
Temperatu
re
01h
Digital
Discrete
05h
01 - Limit
exceeded
Non-fatal
As and
De
–
Trig
Offset
M
–
Processor 2 VRD
Temperature
(P2 VRD Hot)
91h
All
Temperatu
re
01h
Digital
Discrete
05h
01 - Limit
exceeded
Non-fatal
As and
De
–
Trig
Offset
M
–
Processor 3 VRD
Temperature
(P3 VRD Hot)
92h
All
Temperatu
re
01h
Digital
Discrete
05h
01 - Limit
exceeded
Non-fatal
As and
De
–
Trig
Offset
M
–
Processor 4 VRD
Temperature
(P4 VRD Hot)
93h
All
Temperatu
re
01h
Digital
Discrete
05h
01 - Limit
exceeded
Non-fatal
As and
De
–
Trig
Offset
M
–
Processor 1 Memory VRD
Hot 0-1
(P1 Mem01 VRD Hot)
94h
All
Temperatu
re
01h
Digital
Discrete
05h
01 - Limit
exceeded
Non-fatal
As and
De
–
Trig
Offset
A
–
Processor 1 Memory VRD
Hot 2-3
(P1 Mem23 VRD Hot)
95h
All
Temperatu
re
01h
Digital
Discrete
05h
01 - Limit
exceeded
Non-fatal
As and
De
–
Trig
Offset
A
–
Processor 2 Memory VRD
Hot 0-1
(P2 Mem01 VRD Hot)
96h
All
Temperatu
re
01h
Digital
Discrete
05h
01 - Limit
exceeded
Non-fatal
As and
De
–
Trig
Offset
A
–
Processor 2 Memory VRD
Hot 2-3
(P2 Mem23 VRD Hot)
97h
All
Temperatu
re
01h
Digital
Discrete
05h
01 - Limit
exceeded
Non-fatal
As and
De
–
Trig
Offset
A
–