Technical product specification
Appendix C: BMC Sensor Tables Intel
®
Server Board S2600CP and Server System P4000CP TPS
Revision 1.8
Intel order number G26942-005
194
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset
Triggers
Contrib. To
System Status
Assert/
De-
assert
Readable
Value/Off
sets
Event
Data
Rearm
Stand-
by
Baseboard +1.8V Aux
(BB +1.8V AUX)
DCh
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
R, T
A
–
Baseboard +1.1V Stand-
by
(BB +1.1V STBY)
DDh
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
R, T
A
–
Baseboard CMOS Battery
(BB +3.3V Vbat)
DEh
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
R, T
A
–
Baseboard +1.35V P1 Low
Voltage Memory AB
VDDQ
(BB +1.35 P1LV AB)
E4h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
R, T
A
–
Baseboard +1.35V P1 Low
Voltage Memory CD
VDDQ
(BB +1.35 P1LV CD)
E5h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
R, T
A
–
Baseboard +1.35V P2 Low
Voltage Memory AB
VDDQ
(BB +1.35 P2LV AB)
E6h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
R, T
A
–
Baseboard +1.35V P2 Low
Voltage Memory CD
VDDQ
(BB +1.35 P2LV CD)
E7h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
R, T
A
–
Baseboard +3.3V Riser 1
Power Good
(BB +3.3 RSR1 PGD)
EAh
Platform
Specific
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
R, T
A
–
Baseboard +3.3V Riser 2
Power Good
(BB +3.3 RSR2 PGD)
EBh
Platform
Specific
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog
R, T
A
–