Technical product specification

Intel
®
Server Board S2600CP and Server System P4000CP TPS Appendix D: Platform Specific BMC Appendix
Revision 1.8
Intel order number G26942-005
197
Intel
®
Server Chassis P4216XXM (Redundant fans, redundant PSUs)
Chassis-specific sensors
Table 148. Chassis-specific Sensors
Intel
®
Server Chassis
Fan Tachometer
sensors
Fan Presence sensors
Physical security
(Chassis intrusion)
Sensor
FP interrupt (FP NMI Diag
Int)
P4208XXM/
P4308XXM (Fixed
fans, fixed or
redundant PSUs)
System Fan 1(30h)
NA
Physical Scrty (04h)
FP NMI Diag Int (05h)
System Fan 2(31h)
NA
NA
NA
P4208XXM/
P4308XXM/
P4216XXM
(Redundant fans,
redundant PSUs)
System Fan 1 (30h)
Fan 1 Present (40h)
Physical Scrty (04h)
FP NMI Diag Int (05h)
System Fan 2 (31h)
Fan 2 Present (41h)
NA
NA
System Fan 3 (32h)
Fan 3 Present (42h)
NA
NA
System Fan 4 (33h)
Fan 4 Present (43h)
NA
NA
System Fan 5 (34h)
Fan 5 Present (44h)
NA
NA
Hot-plug fan support
Supported on
Intel
®
Server Chassis P4208XXM (Redundant fans, redundant PSUs)
Intel
®
Server Chassis P4308XXM (Redundant fans, redundant PSUs)
Intel
®
Server Chassis P4216XXM (Redundant fans, redundant PSUs)
Fan redundancy support
Supported on
Intel
®
Server Chassis P4208XXM (Redundant fans, redundant PSUs)
Intel
®
Server Chassis P4308XXM (Redundant fans, redundant PSUs)
Intel
®
Server Chassis P4216XXM (Redundant fans, redundant PSUs)
Fan domain definition
Table 149. Fan Domain Definition
Chassis
Fan Domain
Major Components Cooled
(Temperature sensor number)
Fans
(Sensor number)
P4208XXM/
P4308XXM
(Fixed fans,
fixed or
redundant
PSUs)
0
Memory channels C and D (B1h)
Memory channels E and F (B2h)
BMC Temp (23h)
Memory VR (25h)
Baseboard NIC (2Fh)
Server South Bridge (22h)
Hot-swap backplane 1 (29h)
Hot-swap backplane 2 (2Ah)
System Fan 1(30h)
1
P1 Therm Margin (74h)
P2 Therm Margin (75h)
System Fan 2(31h)