Specifications
Appendix C: BMC Sensor Tables Intel® Server Boards S5520HC, S5500HCV, and S5520HCT TPS
Revision 1.8
Intel order number E39529-013
152
Table 82. Integrated BMC Core Sensors
Full Sensor Name
(Sensor name in SDR)
Sensor #
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset
Triggers
Contrib. To
System Status
Assert/De
-assert
Readable
Value/Offs
ets
Event
Data
Rearm
Stand-
by
Power Unit Status
(Pwr Unit Status)
01h All
Power Unit
09h
Sensor
Specific
6Fh
00 - Power down
04 - A/C lost
OK
As and
De
– Trig Offset A X
05 - Soft power
control failure
06 - Power unit
failure
Fatal
Power Unit Redundancy1
(Pwr Unit Redund)
02h
Chassis-
specific
Power Unit
09h
Generic
0Bh
00 - Fully
Redundant
OK
As and
De
– Trig Offset A X
01 - Redundancy
lost
Degraded
02 - Redundancy
degraded
Degraded
03 - Non-
redundant:
sufficient
resources.
Transition from
full redundant
state.
Degraded
04 – Non-
redundant:
sufficient
resources.
Transition from
insufficient state.
Degraded
05 - Non-
redundant:
insufficient
resources
Fatal