SEL Troubleshooting Guide
System Event Log Troubleshooting Guide for Intel
®
S5500/S3420 Series Server Boards Microsoft Windows* Records
Revision 1.1 Intel order number G74211-002 97
14.3 Bug Check / Blue Screen Event Records
When the system experiences a bug check (blue screen), there will be multiple records written to the event log. The first is a Bug Check / Blue
Screen OS Stop/Shutdown Event Record; this can be followed by multiple Bug Check / Blue Screen code OEM records that will contain the
Bug Check / Blue Screen codes. This information can be used to determine what caused the failure.
Table 96: Bug Check / Blue Screen – OS Stop Event Record Typical Characteristics
Byte
Field
Description
8
9
Generator ID
0041h – System Software with an ID = 20h
11
Sensor Type
20h = OS Stop/Shutdown
12
Sensor Number
00h
13
Event Direction and
Event Type
[7] Event direction
0b = Assertion Event
1b = Deassertion Event
[6:0] Event Type = 6Fh (Sensor Specific)
14
Event Data 1
[7:6] – 00b = Unspecified Event Data 2
[5:4] – 00b = Unspecified Event Data 3
[3:0] – Event Trigger Offset = 1h = Runtime Critical Stop (that is, “core dump”, “blue screen”)
15
Event Data 2
Not used
16
Event Data 3
Not used
Table 97: Bug Check / Blue Screen Code OEM Event Record Typical Characteristics
Byte
Field
Description
1
2
Record ID
ID used for SEL Record access.
3
Record Type
[7:0] – DEh = OEM timestamped, bytes 8-16 OEM defined