SEL Troubleshooting Guide

Power Subsystems System Event Log Troubleshooting Guide for Inte S5500/S3420 Series Server Boards
28 Intel order number G74211-002 Revision 1.1
Table 25: Power Supply Temperature Sensors Typical Characteristics
Byte
Field
Description
11
Sensor Type
01h = Temperature
12
Sensor Number
56h = Power Supply 1 Temperature
57h = Power Supply 2 Temperature
13
Event Direction and
Event Type
[7] Event direction
0b = Assertion Event
1b = Deassertion Event
[6:0] Event Type = 01h (Threshold)
14
Event Data 1
[7:6] 01b = Trigger reading in Event Data 2
[5:4] 01b = Trigger threshold in Event Data 3
[3:0] Event Trigger Offset as described in Table 26
15
Event Data 2
Reading that triggered event
16
Event Data 3
Threshold value that triggered event
The following table describes the severity of each of the event triggers for both assertion and deassertion.
Table 26: Power Supply Temperature Sensor Event Trigger Offset Next Steps
Event Trigger Offset
Assertion
Severity
Deassert
Severity
Description
Next Steps
Hex
Description
07h
Upper non-critical
going high
Degraded
OK
An upper non-critical
or critical temperature
threshold has been
crossed.
1. Check for clear and unobstructed airflow into and out of the chassis.
2. Ensure the SDR is programmed and correct chassis has been selected.
3. Ensure there are no fan failures.
4. Ensure the air used to cool the system is within the thermal specifications for the system
(typically below 35°C).
09h
Upper critical
going high
non-fatal
Degraded