SEL Troubleshooting Guide

System Event Log Troubleshooting Guide for Intel
®
S5500/S3420 Series Server Boards Miscellaneous Events
Revision 1.1 Intel order number G74211-002 75
11. Miscellaneous Events
The miscellaneous events section addresses sensors not easily grouped with other sensor types.
11.1 IPMI Watchdog
PCSD server systems support an IPMI watchdog timer, which can check to see whether the OS is still responsive. The timer is disabled by
default, and has to be enabled manually. It then requires an IPMI-aware utility in the operating system that will reset the timer before it expires.
If the timer does expire, the BMC can take action if it is configured to do so (reset, power down, power cycle, or generate a critical interrupt).
Table 76: IPMI Watchdog Sensor Typical Characteristics
Byte
Field
Description
11
Sensor Type
23h = Watchdog 2
12
Sensor Number
03h
13
Event Direction and
Event Type
[7] Event direction
0b = Assertion Event
1b = Deassertion Event
[6:0] Event Type = 6Fh (Sensor Specific)
14
Event Data 1
[7:6] 11B = Sensor-specific event extension code in Event Data 2
[5:4] 00b = Unspecified Event Data 3
[3:0] Event Trigger Offset as describe in Table 77