SEL Troubleshooting Guide
Miscellaneous Events System Event Log Troubleshooting Guide for Intel® S5500/S3420 Series Server Boards
78 Intel order number G74211-002 Revision 1.1
11.3 System Event Log Cleared
The BMC logs a SEL clear event. This is only ever the first event in the SEL. Cause of this event is either a manual SEL clear using Intel
®
SEL
Viewer or some other IPMI-aware utility, or is done in the factory as one of the last steps in the manufacturing process.
This is an informational event only.
Table 79: System Event Log Cleared Sensor Typical Characteristics
Byte
Field
Description
11
Sensor Type
10h = Event Logging Disabled
12
Sensor Number
07h
13
Event Direction and
Event Type
[7] Event direction
0b = Assertion Event
1b = Deassertion Event
[6:0] Event Type = 6Fh (Sensor Specific)
14
Event Data 1
[7:6] – 00b = Unspecified Event Data 2
[5:4] – 00b = Unspecified Event Data 3
[3:0] – Event Trigger Offset = 2 = Log area
reset/cleared
15
Event Data 2
Not used
16
Event Data 3
Not used
11.4 System Event – PEF Action
The BMC is configurable to send alerts for events logged into the SEL. These alerts are called Platform Event Filters (PEF) and are disabled by
default. The user must configure and enable this feature. PEF events are logged if the BMC takes action due to a PEF configuration. The BMC
event triggering the PEF action will also be in the SEL.