SEL Troubleshooting Guide
System Event Log Troubleshooting Guide for Intel
®
S5500/S3420 Series Server Boards Miscellaneous Events
Revision 1.1 Intel order number G74211-002 79
This functionality is built into the BMC to allow it to send alerts (SNMP or other) for any event that gets logged to the SEL. PEF filters are turned
off by default and have to be enabled manually using Intel
®
deployment assistant, Intel
®
syscfg utility, or an IPMI-aware utility.
Table 80: System Event – PEF Action Sensor Typical Characteristics
Byte
Field
Description
11
Sensor Type
12h = System Event
12
Sensor Number
08h
13
Event Direction and
Event Type
[7] Event direction
0b = Assertion Event
1b = Deassertion Event
[6:0] Event Type = 6Fh (Sensor Specific)
14
Event Data 1
[7:6] – 11B = Sensor-specific event extension code in Event Data 2
[5:4] – 00b = Unspecified Event Data 3
[3:0] – Event Trigger Offset = 4 = PEF Action
15
Event Data 2
[7:6] – Reserved
[5] – 1b = Diagnostic Interrupt (NMI)
[4] – 1b = OEM action
[3] – 1b = Power cycle
[2] – 1b = Reset
[1] – 1b = Power off
[0] – 1b = Alert
16
Event Data 3
Not used
11.4.1 System Event – PEF Action – Next Steps
This event gets logged if the BMC takes an action due to PEF configuration. Actions can be sending an alert, or resetting, power cycling, or
powering down the system. There will be another event that has led to the action so you should investigate the SEL and PEF settings to identify
this event, and troubleshoot accordingly.