Service Guide

Hardware Installations and Upgrades
Intel
®
Server Board S5520HC, S5520HCT, and S5500HCV Service Guide 29
Table 6. Heatsink Requirements for Compatible Intel
®
Server Chassis
Intel
®
Server Board
S5520HC/S5520HC
T/S5500HCV
Intel
®
Server
Chassis
Heatsink
Includes
Intel
®
Thermal
Solution STS100C (w/
fan, active mode)
Intel
®
Thermal
Solution STS100A
(Active)
FXXRGTHSIN
K
(Passive Tower
Heatsink)
Y SC5600Base No Y Y N
Y SC5600BRP No Y Y N
Y SC5600LX No N N Required
Y SC5650DP No Y Y N
Y SC5650BRP No Y Y N
Y: Support
N: Not Support
Maximum
CPU Power
support in
Intel
®
Server
Chassis
95 W
80 W
95 W
Boxed
Product Code
BXSTS100C BXSTS100A FXXRGTHSINK
Installing Processor Heatsink(s)
To install processor heatsink(s) in the Intel
®
Server Chassis, follow these instructions:
1. Observe the safety and ESD precautions at the beginning of this book. For more information, see “Safety
Information”.
2. Turn off all peripheral devices connected to the server and turn off the server.
3. Disconnect the AC power cord from the server. Remove the server’s cover and locate the processor
socket. See the document that came with your server chassis for instructions on removing the server’s
cover.
4. If a protective film covers the thermal interface material (TIM) on the underside of the heatsink, remove
the protective film. (Step “A” in Figure 19.)