Technical Product Specification

Intel® Server System SC5650HCBRP TPS Appendix C: BMC Sensor Tables
Revision 1.2
Intel order number E81443-002
191
Full Sensor Name
(Sensor name in SDR)
Sensor #
Platform
Applicability
Sensor Type
Event /
Reading Type
Event Offset
Triggers
Contrib. To
System
Status
Assert /
De-assert
Readable
Value /
Offsets
Event
Data
Rearm
Stand-
by
06 – Redundant:
degraded from
fully redundant
state.
Degraded
07 – Redundant:
Transition from
non-redundant
state.
Degraded
IPMI Watchdog
(IPMI Watchdog)
03h All
Watchdog 2
23h
Sensor
Specific
6Fh
00 - Timer
expired, status
only
01 - Hard reset
02 - Power down
03 - Power cycle
08 - Timer
interrupt
OK As Trig Offset
A X
Physical Security
(Physical Scrty)
04h
Chassis
Intrusion is
chassis-
specific
Physical
Security
05h
Sensor
Specific
6Fh
00 - Chassis
intrusion
OK
As and
De
– Trig Offset
A X
04 - LAN leash
lost
OK
FP Interrupt
(FP NMI Diag Int)
05h
Chassis -
specific
Critical
Interrupt
13h
Sensor
Specific
6Fh
00 - Front panel
NMI / diagnostic
interrupt
OK As Trig Offset
A –
SMI Timeout
(SMI Timeout)
06h All
SMI Timeout
F3h
Digital
Discrete
03h
01 – State
asserted
Fatal
As and
De
– Trig Offset
A –
System Event Log
(System Event Log)
07h All
Event Logging
Disabled
10h
Sensor
Specific
6Fh
02 - Log area
reset / cleared
OK As Trig Offset
A X