Technical Product Specification

Intel® Server System SC5650HCBRP TPS Appendix C: BMC Sensor Tables
Revision 1.2
Intel order number E81443-002
197
Full Sensor Name
(Sensor name in SDR)
Sensor #
Platform
Applicability
Sensor Type
Event /
Reading Type
Event Offset
Triggers
Contrib. To
System
Status
Assert /
De-assert
Readable
Value /
Offsets
Event
Data
Rearm
Stand-
by
Processor 1 Thermal Margin
(P1 Therm Margin)
62h All
Temperature
01h
Threshold
01h
– – Analog
Processor 2 Thermal Margin
(P2 Therm Margin)
63h
Dual
processor
only
Temperature
01h
Threshold
01h
– – Analog
Processor 1 Thermal
Control %
(P1 Therm Ctrl %)
64h All
Temperature
01h
Threshold
01h
[u] [c,nc] Non-fatal
As and
De
Analog Trig Offset
A –
Processor 2 Thermal
Control %
(P2 Therm Ctrl %)
65h
Dual
processor
only
Temperature
01h
Threshold
01h
[u] [c,nc] Non-fatal
As and
De
Analog Trig Offset
A –
Processor 1 VRD Temp
(P1 VRD Hot)
66h All
Temperature
01h
Digital
Discrete
05h
01 - Limit
exceeded
Fatal
As and
De
– Trig Offset
M –
Processor 2 VRD Temp
(P2 VRD Hot)
67h
Dual
processor
only
Temperature
01h
Digital
Discrete
05h
01 - Limit
exceeded
Fatal
As and
De
– Trig Offset
M –
Catastrophic Error
(CATERR)
68h All
Processor
07h
Digital
Discrete
03h
01 – State
Asserted
Non-fatal
As and
De
– Trig Offset
M –
CPU Missing
(CPU Missing)
69h All
Processor
07h
Digital
Discrete
03h
01 – State
Asserted
Fatal
As and
De
– Trig Offset
M –
IOH Thermal Trip
(IOH Thermal Trip)
6Ah All
Temperature
01h
Digital
Discrete
03h
01 – State
Asserted
Fatal
As and
De
– Trig Offset
M –
Note 1: Sensor only present on systems that have applicable redundancy (for instance, a fan or power supply).