Technical Product Specification

Overview IntelĀ® Server System SC5650HCBRP TPS
Revision 1.2
Intel order number E81443-002
8
2.1.1.4 Front Control Panel
Callout Button / LED Name Color
Condition
Description
A Power LED Green
On Power on
Off Power off
B Power Button N/A N/A Powers the system on or off
C NMI Button N/A N/A
Used to force system halt and dump
memory contents to screen or file
D Reset Button N/A N/A Reboots and initializes the system
E NIC1 Activity
Green
On Linked
Blink LAN activity
Off Idle
F NIC2 Activity
Green
On Linked
Blink LAN activity
Off Idle
G Hard Drive Activity Green Blink Hard drive activity
H System Status LED
Green
On System booted and ready
Blink
System ready, but degraded: some CPU
fault, DIMM killed, and so forth
Amber
On
Critical alarm: Critical power module failure,
critical fan failure, voltage (power supply),
voltage, thermal fault, and so forth
Blink
Non-critical failure: Redundant fan failure,
redundant power failure, non-critical power
and voltage, and so forth
Off
Off AC Power off;
Off
Powered Down (DC-off state or S5), and no
degraded, non-critical, critical conditions
exist*
* When the server is powered down (transitions to the DC-off state or S5), the BMC is still on standby power and
retains the sensor and front panel status LED state established before the power-down event. If the system status is
normal when the system is powered down (the LED is in a solid green state), the system status LED will be off.
Figure 5. Front Panel Components