Technical Product Specification
Intel® Server System SC5650HCBRP TPS Power Sub-system
Revision 1.2
Intel order number E81443-002
59
Table 17. AC Line Sag Transient Performance
Duration Sag Operating AC
Voltage
Line
Frequency
Loading Performance Criteria
Continuous 10% Nominal AC
Voltage ranges
50/60 Hz 100%
No loss of function or performance.
0 to 1 AC
cycle
100% Nominal AC
Voltage ranges
50/60 Hz 75%
No loss of function or performance.
> 1 AC cycle >10% Nominal AC
Voltage ranges
50/60 Hz 100%
Loss of function acceptable, self
recoverable.
Table 18. AC Line Surge Transient Performance
Duration Surge Operating AC Voltage Line Frequency Performance Criteria
Continuous 10% Nominal AC Voltages 50/60 Hz No loss of function or performance.
0 to ½ AC
cycle
30% Mid-point of nominal AC
Voltages
50/60 Hz
No loss of function or performance.
4.1.2.5 AC Line Fuse
The power supply has a single line fuse on the Line (Hot) wire of the AC input. The line fusing is
acceptable for all safety agency requirements. The input fuse is a slow blow type. AC inrush
current will not cause the AC line fuse to blow under any conditions. All protection circuits in the
power supply will not cause the AC fuse to blow unless a component in the power supply failed.
This includes DC output load short conditions.
4.1.2.6 AC In-rush
AC line in-rush current does not exceed 55A peak for up to one-quarter of the AC cycle, after
which the input current is no more than the specified maximum input current. The peak in-rush
current is less than the ratings of its critical components (including input fuse, bulk rectifiers, and
surge limiting device).
The power supply meets the in-rush requirements for any rated AC voltage, during turn on at
any phase of AC voltage, during a single cycle AC dropout condition, as well as upon recovery
after AC dropout of any duration, and over the specified temperature range (T
op
).
4.1.2.7 Susceptibility Requirements
The power supply meets the following electrical immunity requirements when connected to a
cage with an external EMI filter that meets the criteria defined in the SSI document EPS Power
Supply Specification. For further information on Intel standards, please request a copy of the
Intel Environmental Standards Handbook.