Report
S5000PSLSASR Errata and Contingencies
Testing Exceptions for S5000PSLSASR Windows Server 2008
Data in this section reflects product data and test exceptions listed in section 2 of the S5000PSLSASR
Readme file at time of WLP First-Time submission ID Number 1287148.
Failure type
(Contingency, Errata, Incident)
Operating system
(Windows XP, Windows 2000, etc.)
ID number
Windows Server 2008 x86 Errata 1110
BitLocker Drive Encryption BIOS Interface Logo Test
Failing test name
Applicable error message
(Type N/A if the error message
or failing text is excessive or if
there is no text)
For platforms without Trusted Platform Modules (TPM), the WLK
1.1 kit has an issue which randomly causes the BitLocker Drive
Encryption BIOS Interface Logo Test to fail.
Additional information
(for example, test system in a
multiple system configuration)
Failure type
(Contingency, Errata, Incident)
Operating system
(Windows XP, Windows 2000, etc.)
ID number
Windows Server 2008 x86 Errata 887
PCI Harware Compliance Test for Systems Running Windows Vista
(PCIHCT)
Failing test name
Applicable error message
(Type N/A if the error message
or failing text is excessive or if
there is no text)
Bit 10 (Interrupt Disable) in the Command register (offset 4h) in
the Header table must be read-writable if the device supports an
interrupt.
Additional information
(for example, test system in a
multiple system configuration)
Failure type
(Contingency, Errata, Incident)
Operating system
(Windows XP, Windows 2000, etc.)
ID number
Windows Server 2008 x86 Errata 316
PCI Hardware Compliance Test
Failing test name
Applicable error message
(Type N/A if the error message
or failing text is excessive or if
there is no text)
Bit range 15:8 (Bus Number)in the PCI-X Bridge Status register
(offset 4h) in the PCI-X Capability table must be read-only.
RESOLUTION: The following assertion failure is allowed
EBA19FF0-AB40-4D74-AC05-4ABE22D356BD
Additional information
(for example, test system in a
multiple system configuration)
April 8, 2008 11