Report
S5000XSLSATA Errata and Contingencies
January 10, 2007 11
Testing Exceptions for S5000XSLSATA Windows Server 2000
As of November 1
st
, 2004, Windows 2000 logs are no longer required for submission. Windows will only get a
“Supported” status when submitted along with Windows Server 2003.
Testing Exceptions for S5000XSLSATA Windows Server 2003
Data in this section reflects product data and test exceptions listed in section 2 of the S5000XSLSATA
Readme file at time of WLP First-Time submission ID Number 1200724.
Operating system
(Windows XP, Windows 2000, etc.)
Failure type
(Contingency, Errata, Incident)
ID number
Windows Server 2003 EE x86 Errata 1522
Failing test name
PCI Compliance Test
Applicable error message
(Type N/A if the error message
or failing text is excessive or if
there is no text)
2CC.2C8 : DEVICE INFO : Intel(R) 5000 Series Chipset PCI Express x4 Port 3 - 25E3
2CC.2C8 : DEVICE INFO :
PCI\VEN_8086&DEV_25E3&SUBSYS_00000000&REV_12\3&61aaa01&0&18
2CC.2C8 : +TEST+SEV2 : FAIL: 4.52.3 - If the device uses an interrupt, the Interrupt Line
field must be implemented as read/write.
Additional information
(for example, test system in a
multiple system configuration)
Operating system
(Windows XP, Windows 2000, etc.)
Failure type
(Contingency, Errata, Incident)
ID number
Windows Server 2003 EE x86 Errata 1306
Failing test name
PCI Compliance
Applicable error message
(Type N/A if the error message
or failing text is excessive or if
there is no text)
2CC.2C8 : DEVICE INFO : Intel(R) 6311ESB/6321ESB PCI Express Upstream Port - 3500
2CC.2C8 : DEVICE INFO :
PCI\VEN_8086&DEV_3500&SUBSYS_00000000&REV_01\4&24a5c8eb&0&0010
2CC.2C8 : +TEST+SEV2 : FAIL: - A PCI-Express device that generates interrupts must
have an MSI or MSI-X capability.
Additional information
(for example, test system in a
multiple system configuration)
Operating system
(Windows XP, Windows 2000, etc.)
Failure type
(Contingency, Errata, Incident)
ID number