Command Line Tool 2 User Guide
Intel
®
RAID Controller Command Line Tool 2 User Guide
AdpBootDrive
Description
Set or Display Bootable Virtual Drive ID
Syntax
CmdTool2 -AdpBootDrive {-Set -L[drive] | -physdrv[E0:S0]} | -Get -a[controller]
Parameters
-a[controller]: The RAID controller affected by the command
-Set: Sets the virtual drive as bootable so that during the next reboot, the BIOS will look for a
boot sector in the specified virtual drive.
-Get: Display the current bootable Virtual Drive ID
Example
CmdTool2 -AdpBootDrive -Set -L0 -a0
CmdTool2 -AdpBootDrive -Get -a0
AdpCacheFlush
Description
Flush the RAID controller cache. If the MegaRAID system must be powered down rapidly, you
must flush the contents of the cache memory to preserve data integrity.
Syntax
CmdTool2 -AdpCacheFlush -a[controller]
Parameters
-a[controller]: The RAID controller affected by the command
Example
CmdTool2 -AdpCacheFlush -a1