Command Line Tool 2 User Guide
Intel
®
RAID Controller Command Line Tool 2 User Guide
CCRate: Consistency check rate. Values: 0 to 100.
ReconRate: Reconstruction rate. Values: 0 to 100.
SpinupDriveCount: Max number of drives to spin up at one time. Values: 0 to 255.
SpinupDelay: Number of seconds to delay among spinup groups. Values: 0 to 255.
CoercionMode: Drive capacity Coercion mode. Values: 0 - None, 1 - 128 Mbytes, 2 - 1 Gbytes.
ClusterEnable: Cluster is enabled or disabled. Values: 0 - Disabled, 1 - Enabled.
PredFailPollInterval: Number of seconds between predicted fail polls. Values: 0 to 65535.
BatWarnDsbl: Disable warnings for missing battery or missing hardware. Values: 0 - Enabled, 1 -
Disabled.
EccBucketSize: Size of ECC single-bit-error bucket. Values: 0 to 255.
EccBucketLeakRate: Leak rate (in minutes) of ECC single-bit-error bucket. Values: 0 to 65535.
AbortCCOnError: Abort the consistency check if an error is found.
AlarmEnbl: Set alarm to Enabled.
AlarmDsbl: Set alarm to Disabled.
AlarmSilence: Silence an active alarm.
SMARTCpyBkEnbl: Enable copyback operation on Self-Monitoring Analysis and Reporting
Technology (SMART) errors.
Copyback is initiated when the first SMART error occurs on a drive that is part of a virtual drive.
AutoDetectBackPlaneDsbl: Detect automatically if the backplane has been disabled.
CopyBackDsbl: Disable or enable the copyback operation.
LoadBalanceMode: Disable or enable the load balancing mode.
NCQEnbl: Enable the native command queueing.
NCQDsbl: Disable the native command queueing.
SSDSMARTCpyBkEnbl: Enable copyback operation on Self-Monitoring Analysis and Reporting
Technology (SMART) errors on a Solid State Drive (SSD). Copyback is initiated when the first
SMART error occurs on a SSD that is part of a virtual drive.
MaintainPdFailHistoryEnbl: Enable maintenance of the history of a failed drive.
EnblSpinDownUnConfigDrvs: Enable spindown of unconfigured drives.
EnblSSDPatrolRead: Enable the patrol read operation (media scan) on a SSD.