Command Line Tool 2 User Guide

AutoEnhancedImportEnbl: Enable the controller to import a foreign configuration automatically at
boot (known as automatic enahanced import).
AutoEnhancedImportDsbl: Do not allow the controller to import a foreign configuration automatically.
UseFDEOnlyEncrypt: Use encryption on FDE drives only.
PrCorrectUncfgdAreas: Have the patrol read operation correct media errors if the value is 1.
DsblSpinDownUnConfigDrvs: Disable the automatic spindown of unconfigured drives.
BootWithPinnedCache: If the value is 1 then controller is allowed boot with pinned cache. If the value
is 0 then this property is disabled.
ExposeEnclDevicesEnbl: If the value is 1, then it enables device drivers to expose enclosure devices.
If the value is 0, the enclosure devices are hidden, not exposed.
DsblCacheBypass: If the value is 1, then cache bypass performance improvement feature is disabled.
If the value is 0, then cache bypass performance improvement feature is enabled.
Note: Intel recommands the default rebuild rate of 30 percent, and the default patrol read rate of
30 percent.
Example
CmdTool2 -AdpSetProp -AlarmEnbl -a0
CmdTool2 -AdpSetProp -NCQEnbl -a0
AdpSetSASA
Description
Set SAS address of the specified controllers.
Syntax
Cmdtool2 -AdpSetSASA str[0-64] -a[controller]
Parameters
-a[controller]: The RAID controller affected by the command
str[0-64]: This string must be a 64-digit hexadecimal number.
Example
cmdTool2 -AdpSetSASA str0 -a1