Command Line Tool 2 User Guide
Intel
®
RAID Controller Command Line Tool 2 User Guide
-r50: To create RAID 50 array
-r60: To create RAID 60 array
-Array0[E0:S0, E1:S1]: Uing the specifid enclosure ID and slot ID drives to create Array0
-Array1[E0:Sn] [...]: Uing the specifid enclosure ID and slot ID drives to create Array1
-WT: Set the array to write-through
-WB: Set the array to write-back
-RA: Set the array to read-ahead
-NORA: Set the array to no read-ahead
-ADRA: Otional parameter to define adptive read ahead
-Direct: Otional parameter to define direct I/O
-CachedBadBBU|NoCachedBadBBU: Specifies whether to use write cache when the BBU is
bad
-strpszM: Optional parameter to set the stripe size (only 64 Kbyte is supported)
Example
CmdTool2 -CfgSpanAdd -r10 -Array0[252:0, 252:1] -Array1[252:2, 252:3] -a0
CfgSscdAdd
Description
Create a Solid State Drive Cache Drive (SSCD) to use as secondary cache
Syntax
CmdTool2 -CfgSscdAdd -Physdrv[E0:S0,...] {-Name LdNamestring}-a[controller]
Parameters
-a[controller]: The RAID controller affected by the command
-Physdrv[E0:S0,...]: Specifies the physical drive enclosure and the slots to use to construct a drive
group.
-Name LdNamestring: This is the name given to the SSD cache drive.