SEL Troubleshooting Guide
Miscellaneous Events
System Event Log Troubleshooting Guide for PCSD
Platforms Based on Intel
®
Xeon
®
Processor E5 4600/2600/2400/1600/1400 Product Families
106 Intel order number G90620-003 Revision 1.2
Table 81: System Event – PEF Action Sensor Typical Characteristics
Byte
Field
Description
11
Sensor Type
12h = System Event
12
Sensor Number
08h
13
Event Direction and
Event Type
[7] Event direction
0b = Assertion Event
1b = Deassertion Event
[6:0] Event Type = 6Fh (Sensor Specific)
14
Event Data 1
[7:6] – 11B = Sensor-specific event extension code in Event Data 2
[5:4] – 00b = Unspecified Event Data 3
[3:0] – Event Trigger Offset = 4h = PEF Action
15
Event Data 2
[7:6] – Reserved
[5] – 1b = Diagnostic Interrupt (NMI)
[4] – 1b = OEM action
[3] – 1b = Power cycle
[2] – 1b = Reset
[1] – 1b = Power off
[0] – 1b = Alert
16
Event Data 3
Not used
11.4.1 System Event – PEF Action – Next Steps
This event gets logged if the BMC takes an action due to PEF configuration. Actions can be sending an alert, along with possibly
resetting, power cycling, or powering down the system. There will be another event that has led to the action so you need to
investigate the SEL and PEF settings to identify this event, and troubleshoot accordingly.