SEL Troubleshooting Guide

Power Subsystems
System Event Log Troubleshooting Guide for PCSD
Platforms Based on Intel
®
Xeon
®
Processor E5 4600/2600/2400/1600/1400 Product Families
38 Intel order number G90620-003 Revision 1.2
This sensor is only used for triggering SEL to indicate node or power auto shutdown assertion or deassertion.
Table 19: Node Auto Shutdown Sensor Typical Characteristics
Byte
Field
Description
11
Sensor Type
09h = Power Unit
12
Sensor Number
B8h
13
Event Direction and
Event Type
[7] Event direction
0b = Assertion Event
1b = Deassertion Event
[6:0] Event Type = 03h (“digital” discrete)
14
Event Data 1
[7:6] 00b = Unspecified Event Data 2
[5:4] 00b = Unspecified Event Data 3
[3:0] Event Trigger Offset
1h = State Asserted
15
Event Data 2
Not used
16
Event Data 3
Not used
4.3.3.1 Node Auto Shutdown Sensor Next Steps
This event is accompanied by specific power supply errors (AC lost, PSU failure, and so on) or other system events. Troubleshoot
these events accordingly.
4.4 Power Supply
The BMC monitors the power supply subsystem.
4.4.1 Power Supply Status Sensors
These sensors report the status of the power supplies in the system. When a system first AC applied or removed, it can log an event.
Also if there is a failure, predictive failure, or a configuration error, it can log an event.