Server Management Guide

Baseboard Management Controller
18 Intel
®
Server Boards and Server Platforms Server Management Guide
Table 7. Shared Ethernet ports with BMC
Intel
®
Server Boards
System Ethernet port shared with the BMC
Intel
®
S3200 Server Boards
On-board NIC1
Intel
®
Server Board X38ML
On-board NIC1
The following figure displays the location for NIC1 and NIC2 on Intel
®
server system SR1520ML to
serve as a reference.
NOTE
The location of the on-board NICs may be slightly different on other Intel
®
server boards.
A
On-board NIC1
B
On-board NIC2
Figure 5. Rear connectors of the Intel
®
SR1520ML server system
2.3.5 BMC Users
The BMC supports the IPMI 2.0 user model, including User ID 1 support. 15 user IDs are supported.
These 15 users can be assigned to any channel. The following restrictions are placed on user-related
operations:
User names for User IDs 1 and 2 cannot be changed. These will always be “” (Null) and “root”
respectively.
User 2 (“root”) will always have the administrator privilege level.
All user passwords (including passwords for User 1 and User 2) may be modified.
User IDs 3-15 may be used freely, with the condition that user names are unique. Therefore, no
other users can be named as “” (Null), “root,” or any other existing user name.