Service Guide
Server System Features
Intel®
Server System SC5650HCBRP Service Guide 7
Callout Button/LED Name Color Condition Description
Off
Off AC Power off;
Off
Powered Down (DC-off state or S5), and no
degraded, non-critical, critical conditions
exist*
/
NOTE
When the server is powered down (transitions to the DC-off state or S5), the BMC is still on standby power and
retains the sensor and front panel status LED state established before the power-down event. If the system
status is normal when the system is powered down (the LED is in a solid green state), the system status LED
will be off.
Figure 6. Front Panel Components
Mechanical Locks
The Intel
®
Server System SC5650HCBRP chassis support the installation of a padlock loop (see letter “A” in
the following figure) at the rear of the chassis. Additionally, the system ships with a two-position mechanical
lock (see letter “B”) on the front bezel assembly to prevent access to the hard drives and the interior of the
system.
Figure 7. Mechanical Locks
Peripheral Devices
The Intel
®
Server System SC5650HCBRP provides locations and hardware for installing hard dives, a floppy
drive, CD-ROM driver, DVD-ROM drive, or tape drive. You must purchase the drives separately.
/
NOTE
It is recommended that screws be used to secure large devices if shipping system integrated.
Hard Disk Drives
The Intel
®
Server System SC5650HCBRP ships with one expander hot-swap hard dive cage capable of
supporting up to six 3.5-inch hard drives at 3GB/s. Power requirements for each individual hard drive may limit