Service Guide

Hardware Installations and Upgrades
34 Intel
®
Server System SC5650HCBRP Service Guide
Figure 26. Installing System Fan Duct
Installing and Removing Memory
The silkscreen on the Intel
®
Server System SC5650HCBRP server board for the DDR3 DIMM sockets displays
DIMM_A1, DIMM_A2, DIMM_B1, DIMM_B2, DIMM_C1, DIMM_C2, DIMM_D1, DIMM_D2, DIMM_E1,
DIMM_E2, DIMM_F1, and DIMM_F2, starting from the inside of the board. See “Memory” for a discussion on
memory installation rules, requirements, and options. See “Additional Information and Software”
.
Installing DIMMs
To install DIMMs, follow these steps:
1. Observe the safety and ESD precautions at the beginning of this book. For more information, see “Safety
Information”.
2. Turn off all peripheral devices connected to the server and turn off the server.
3. Disconnect the AC power cord from the server.
4. Remove the server’s cover and fan duct, and locate the DIMM sockets. See “Memory”.