Intel® Server System SC5650HCBRP Service Guide 35
Figure 27 .Installing Memory
5. Make sure the clips at either end of the DIMM socket(s) are pushed outward to the open position (Step “A”
in Figure 27).
6. Holding the DIMM by the edges, remove it from its anti-static package.
7. Position the DIMM above the socket. Align the small notch in the bottom edge of the DIMM with the key in
the socket (Step “B” in Figure 27).
8. Insert the bottom edge of the DIMM into the socket (Step “C” in Figure 27).
9. When the DIMM is inserted, push down on the top edge of the DIMM until the retaining clips snap into
place (Step “D” in Figure 27).
10. Visually check that each latch is fully closed and correctly engaged with each DIMM edge slot (Step “E” in
Figure 27).
11. Replace the system fan duct and server’s cover. Reconnect the AC power cord.
Removing DIMMs
To remove a DIMM, follow these steps:
1. Observe the safety and ESD precautions at the beginning of this book. For more information, see “Safety
Information”.
2. Turn off all peripheral devices connected to the server, and turn off the server.
3. Remove the AC power cord from the server.
4. Remove the server’s cover and fan duct.
5. Gently spread the retaining clips at each end of the socket. The DIMM lifts from the socket.
6. Holding the DIMM by the edges, lift it from the socket, and store it in an anti-static package.
7. Reinstall and reconnect any parts you removed or disconnected to reach the DIMM sockets.
8. Replace system fan duct, and server’s cover. Reconnect the AC power cord.
Installing or Replacing the Processor
/
NOTE
Use the following instructions to install or replace a processor instead of using the
instructions that came with the processor.