Service Guide

Hardware Installations and Upgrades
38 Intel
®
Server System SC5650HCBRP Service Guide
Figure 32. Install the processor
11. Close the load plate and socket lever: Close the load plate all the way as shown in Figure 33 (Step “A”),
push down on the load plate (Step “B” in Figure 33), and close the socket lever and ensure the load plate
tab engages under the socket lever when fully closed (Step “C” in Figure 33).
Figure 33. Close Load Plate and Socket Lever
12. Install the heatsink(s). See Installing the Processor Heatsink(s) for instructions.
Replacing the Processor
1. Observe the safety and ESD precautions at the beginning of this book. For more information, see “Safety
Information”.
2. Turn off all peripheral devices connected to the server and turn off the server.
3. Disconnect the AC power cord from the server.
4. Remove the server’s cover and fan duct, locate the processor socket.
5. If needed, disconnect the active processor heatsink fan cable from the server board.
6. Loosen the four captive screws on the corner of the heatsink.
7. Twist the heatsink slightly to break the seal between the heatsink and the processor.
8. Lift the heatsink from the processor. If it does not pull up easily, twist the heatsink again. Do not force the
heatsink from the processor – doing so could damage the processor.
9. Lift the processor socket lever.
10. Raise the processor socket load plate.
11. Remove the processor.
12. If installing a replacement processor, see “Installing the Processor”.
13. Reinstall and reconnect any parts you removed or disconnected to reach the processor sockets. See the
documentation that came with your chassis for instructions on installing chassis components.
14. Replace fan duct, and server’s cover. Reconnect the AC power cord.