Service Guide
Hardware Installations and Upgrades
40 Intel
®
Server System SC5650HCBRP Service Guide
5. Align the active heatsinks in the Intel
®
Server Chassis SC5650 and Intel
®
Server Chassis SC5600
(excluding Intel
®
Server Chassis SC5600LX) to let airflow go through to the center of the board (Step “B”
for active heatsink in Figure 34). Align the passive tower heatsinks (FXXRGTHSINK) fins to fit the Intel
®
Server Chassis SC5600LX air duct (Step “B” for passive heatsink in Figure 34).
6. Using a #2 Philips* screwdriver to tighten each fastener diagonally according to the white-circled numbers
in Figure 34. (Step “C” in Figure 34).
7. Securely re-tighten each fastener again in the same order as performed in Step 6. (Step “D” in Figure 34.)
Callout Processor Fan Connector Callout Processor Fan Connector
A. CPU_1 B. CPU_2
Figure 35. Locating Active Heatsink Cable Connections
8. Attach an active heatsink fan cable to the server board. (Step “E” in Figure 34). See Figure 35 to locate
the processor fan headers.
9. Reinstall and reconnect any parts you removed or disconnected to reach the processor sockets. Refer to
the documentation that came with your chassis for instructions on installing chassis components.
10. Replace fan duct, and the server’s cover. Reconnect the AC power cord. Refer to the documentation that
came with your chassis for instructions on installing the cover.
Installing or Removing a DVD-ROM or CD-ROM Drive
CAUTION
CD-ROM and DVD-ROM drives are NOT hot-swappable. Before removing or replacing the drive, you must first
take the server out of service, turn off all peripheral devices connected to the system, turn off the system by
pressing the power button, and unplug the AC power cord from the system or wall outlet.
Installing a DVD-ROM or CD-ROM Drive
1. Observe the safety and ESD precautions listed in “Appendix B: Safety Information”.