Service Guide

Hardware Installations and Upgrades
Intel® Server System SC5650HCBRP Service Guide 59
Figure 65. Inserting Hot Swap Drive Cage into Chassis
10. Make the backplane and server board/RAID controller card cable connections. Cable instructions differ
depending upon SAS controller device. Refer to the documentation that came with your RAID controller
card for instructions on connecting backplane cables to your RAID controller card. Connect HSBP_IPMB
cable to Server Board HSPB_A headers.
11. Reinstall system fan duct and chassis left side cover if available.
CAUTIONS
It is critical that you connect the SAS data cables correctly from the SAS backplane to your RAID Controller card.
Failure to do so may result in data loss.
The SAS cables are labeled to correspond with the backplane data ports. Make sure to connect the cables correctly
to avoid confusion later.
Installing an Additional Power Supply Module
/
NOTE
This install procedure only applies to a chassis with redundant power supply
capability.
WARNING
Hazardous conditions, power supply: Hazardous voltage, current, and energy levels
are present inside the power supply. There are no user-serviceable parts inside it;
servicing of the power supply should be done only by technically qualified personnel.
1. Observe the safety and ESD precautions listed in “Appendix B: Safety Information”.
2. Insert finger into hole in middle of filler panel and remove filler panel from chassis.