Service Guide

Hardware Installations and Upgrades
62 Intel
®
Server System SC5650HCBRP Service Guide
Replacing a Hot Swap Power Supply Cage
WARNING
Hazardous conditions, power supply: Hazardous voltage, current, and energy levels
are present inside the power supply. There are no user-serviceable parts inside it;
servicing of the power supply should be done only by technically qualified personnel.
1. Observe the safety and ESD precautions listed in “Appendix B: Safety Information”.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the left side cover. For instructions, see “Removing the Left Side Cover”.
4. Press up on green latch (see letter “A”) while pulling on handle to remove hot swap power supply module
from chassis.
Figure 70. Removing Hot Swap Power Supply Module(s)
5. Remove second (redundant) hot swap power supply module (or filler panel), if one is present.
6. Disconnect all internal power cables from chassis components and server board.
7. Remove two internal screws (see letter “A” in the following figure) securing hot swap power supply cage to
chassis.